Home About us Editorial board Search Ahead of print Current issue Archives Submit article Instructions Subscribe Contacts Login 
  Users Online: 137 Home Print this page Email this page Small font sizeDefault font sizeIncrease font size  
ORIGINAL ARTICLE
Year : 2012  |  Volume : 2  |  Issue : 1  |  Page : 52-57

Dosimetric evaluation of 3Dconformal acceleratedpartial-breast irradiation vs. whole-breast irradiation: A comparative study


1 Department of Radiotherapy and Oncology, Postgraduate Institute of Medical Education and Research, Chandigarh, Punjab, India
2 Department of General Surgery, Postgraduate Institute of Medical Education and Research, Chandigarh, Punjab, India

Correspondence Address:
Ritesh Kumar
Department of Radiotherapy and Regional Cancer Center, Postgraduate Institute of Medical Education and Research, Chandigarh
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2229-516X.96810

Rights and Permissions

Background : Conventional early breast cancer treatment consists of lumpectomy followed by whole-breast irradiation (WBI) therapy. Accelerated partial-breast irradiation (APBI) is also an approach to post-lumpectomy radiation for early breast cancer. Aim : The purpose of this study is to compare two different external-beam APBI techniques using three-dimensional (3D) conformal radiation therapy (3DCRT), with conventional whole-breast irradiation based on the radiation conformity index, dose homogeneity index, and dose to organs at risk. Materials and Methods : WBI treatment plans were compared with two different 3DCRT APBI plans for each of 15 patients (8 with right sided lesions, 7 with left sided lesions). The first APBI plan (APBI 1) used two small coplanar fields conformed to the planning target volume (PTV) using multileaf collimators (MLCs) and wedges, while the other APBI plan (APBI 2) used three non-coplanar fields conformed to the PTV using MLCs and wedges. Results : Both the APBI techniques improved the conformity index significantly over whole-breast tangents while maintaining dose homogeneity and not causing significant increase in dose to organs at risk. Conclusion : Both the 3DCRT APBI techniques are technically feasible and dosimetrically appealing,with better target coverage and relative sparing of normal critical organs


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed3050    
    Printed110    
    Emailed0    
    PDF Downloaded360    
    Comments [Add]    
    Cited by others 1    

Recommend this journal